Menlo
AssembleRight Leg ModuleSub-assembly A

Step 2: Install Actuator ID 9

Route the actuator cable through part 500_03C, install actuator ID 9, and secure it with eight bolts.

Parts needed

PartCount
Actuator ID 9 with connected cables from Step 11
1
M4x10 Socket Bolts8
ThreadlockerAs needed

Instructions

Place part flat on the surface such that the surface with an L shape groove is pointing upward toward the ceiling. The long hollow shaft should be facing toward you.

Step 2: Install Actuator ID 9 - Instruction 1

The hollow shaft contains a cable channel. Take the free connector of the double-ended XT30 cable and route the cable through the channel to the other side.

Step 2: Install Actuator ID 9 - Instruction 2

Take actuator EC-A3814-H14-107 (ID 9) and align its port with the cable channel. Then slowly slide the actuator inside the hollow shaft until all the threaded holes on the actuator shell align with the inserts on part .

Step 2: Install Actuator ID 9 - Instruction 3

Take 8 – M4x10 Socket bolts and lightly tighten them into the holes on part to align with the actuator.

Step 2: Install Actuator ID 9 - Instruction 4

After the parts are aligned:

  • remove each of the 8 – M4x10 Socket bolts in a star formation,
  • apply threadlocker,
  • then tighten them back to secure Part and the actuator together.

How is this guide?

On this page