Step 2: Install Actuator ID 3
Route the actuator cable through part 600_03C, install actuator ID 3, and secure it with eight bolts.
Parts needed
| Part | Count |
|---|---|
| Actuator ID 3 with connected cables from Step 1 | 1 |
| 1 | |
| M4x10 Socket Bolts | 8 |
| Threadlocker | As needed |
Instructions
Place part flat on the surface such that the surface with an L shape groove is pointing upward toward the ceiling. The long hollow shaft should be facing toward you.
The hollow shaft contains a cable channel. Take the free connector of the double-ended XT30 cable and route the cable through the channel to the other side.
Take actuator EC-A3814-H14-107 (ID 3) and align its port with the cable channel. Then slowly slide the actuator inside the hollow shaft until all the threaded holes on the actuator shell align with the inserts on part .
Take 8 – M4x10 Socket bolts and lightly tighten them into the holes on part to align with the actuator.
After the parts are aligned:
- remove each of the 8 – M4x10 Socket bolts in a star formation,
- apply threadlocker,
- then tighten them back to secure Part and the actuator together.
How is this guide?
Step 1: Set Up Actuator ID 3
Connect the XT30 cable connectors to actuator ID 3, route the 280 mm cable through the actuator shaft, and leave the 150 mm cable and its free connector accessible.
Step 3: Install Actuator ID 4
Install actuator ID 4 in its mount, connect it to actuator ID 3, and secure the assembly.