Menlo
AssemblePelvis ModuleAttach Left & Right Legs

Step 7: Attach the Right Leg Module to the Pelvis

Solder the corresponding conductors from the right hip roll and hip yaw cable leads, then attach the right leg module with five M5x25 socket bolts.

Parts needed

PartCount
Pelvis assembly containing right hip roll actuator ID 81
Completed Right Leg Module1
M5x25 socket bolts5
ThreadlockerAs needed
Approved soldering and insulation suppliesAs needed

Instructions

Take the Right Leg Module and align part with the actuator EC-A5013-H17-100 (ID 8) .

Twist the Right Leg body such that you can see the 5 holes on part clearly and make sure it is aligned with the holes on the actuator shaft.

Solder each corresponding conductor from the cable leads of right hip roll actuator ID 8 to the cable leads of right hip yaw actuator ID 9 , following the released pinout.

Please follow our video for the soldering process

Please follow our video for the soldering process to make sure that the connection is made correctly else it can cause signal infidelity in the system.

Take 5 - M5x25 Socket bolt and lightly tighten them into the 5 holes on part to align with the Right Hip Roll (ID 8) actuator.

After the parts are aligned:

  • remove each of the 5 – M5x25 socket bolts in a star formation,
  • apply threadlocker,
  • then tighten them back to secure Part and the actuator together.

Twist the Right leg body back to its original position so that the leg is straight and front facing.

How is this guide?

On this page