Step 7: Attach the Right Leg Module to the Pelvis
Solder the corresponding conductors from the right hip roll and hip yaw cable leads, then attach the right leg module with five M5x25 socket bolts.
Parts needed
| Part | Count |
|---|---|
| Pelvis assembly containing right hip roll actuator ID 8 | 1 |
| Completed Right Leg Module | 1 |
| M5x25 socket bolts | 5 |
| Threadlocker | As needed |
| Approved soldering and insulation supplies | As needed |
Instructions
Take the Right Leg Module and align part with the actuator EC-A5013-H17-100 (ID 8).
Twist the Right Leg body such that you can see the 5 holes on part clearly and make sure it is aligned with the holes on the actuator shaft.
Solder each corresponding conductor from the cable leads of right hip roll actuator ID 8 to the cable leads of right hip yaw actuator ID 9, following the released pinout.
Use an approved soldering procedure
Prepare, solder, insulate, and inspect the connection using an approved procedure before continuing.
Take 5 - M5x25 Socket bolt and lightly tighten them into the 5 holes on part to align with the Right Hip Roll (ID 8) actuator.
After the parts are aligned:
- remove each of the 5 – M5x25 socket bolts in a star formation,
- apply threadlocker,
- then tighten them back to secure Part and the actuator together.
Twist the Right leg body back to its original position so that the leg is straight and front facing.
How is this guide?
Step 6: Install the Left Hip Roll Actuator
Mount and connect the left hip roll actuator, then secure its outer support components.
Step 8: Attach the Left Leg Module to the Pelvis
Solder the corresponding conductors from the left hip roll and hip yaw cable leads, then attach the left leg module with five M5x25 socket bolts.